12V vs 15V Landscape Transformer Taps
Higher taps can offset voltage drop on a low-voltage run. They are not a universal 15 V setting, and EMCOD families do not all print the same tap set.
Written by Projekt Supply Lighting Team. Last reviewed September 17, 2026. First published September 17, 2026. Part of the EMCOD LED driver and transformer guide.
Why landscape transformers have multiple taps
- Many low-voltage landscape fixtures are designed around a nominal 12 V operating window.
- Cable resistance drops voltage as current travels. The voltage that matters is at the fixture, not only at the transformer terminal.
- A higher tap raises starting voltage so a long or loaded run can still arrive inside the fixture window.
- The correct tap depends on actual load, conductor, length, and fixture limits. It is not “long run = highest tap.”
- Measure voltage at the load after install. Do not assume the tap label equals fixture voltage.
Nominal 12 V landscape systems
Many landscape fixtures are specified around a 12 V operating window. A 15 V transformer terminal is not “brighter 12 V.” It is extra starting voltage that can be consumed by cable drop. If the fixture then receives more than its manufacturer allows, it can run hot or fail. Check voltage at the load.
EMCOD family evidence — not a universal tap set
Public product records may only support a Multi-tap label. The tap voltages below are tied to sourced manufacturer documents already in this project. Do not copy them onto every MPN in the family.
| Family | Sourced tap evidence | Evidence note |
|---|---|---|
| ESL | 12 VAC and 15 VAC on sourced ESL75W / ESL100W sheets | ESL100W spec: magnetic; timer and photocell build-in options; 12/15 VAC taps. |
| Simple Series | 12 VAC and 15 VAC on the sourced SS120W sheet | SS120W spec: magnetic; timer and photocell build-in options; 12/15 VAC taps; 120 W max. |
| EMT | EMT-E: 12/13/14/15 VAC. EMT-22E: 12–22 VAC. Confirm the exact MPN. | EMT150SS-E spec: 12/13/14/15 VAC; timer and photocell build-in options. EMT300SS-22E spec: 12–22 VAC taps. |
| SMT | Install: 12 V, 13 V, or 15 V taps in each of three zones | SMT300W spec: 300 W max, 100 W per circuit. Install: Wi-Fi 2.4 GHz, Tuya/Smart Life, three zones, app timer. |
- Public catalog / PDP records may only support a Multi-tap label until the selected specification lists voltages. Do not copy a sibling MPN’s tap set onto every EMT model.
- Sourced ESL and Simple sheets print 12 VAC and 15 VAC. That is manufacturer-sheet evidence for those cited documents, not a claim that every landscape transformer has only those two taps.
- EMT-E sourced sheets print 12/13/14/15 VAC. EMT-22E sourced sheets print a 12–22 VAC set. Those are different products.
- SMT install documentation lists 12/13/15 V per zone. Confirm the selected SMT MPN install sheet.
Exact models used as identification examples: ESL100W (sourced ESL sheet prints 12/15 VAC), EMT300SS-E (do not invent this MPN’s tap voltages from a sibling), EMT300SS-22E (sourced 12–22 VAC set), and SMT300W (install lists 12/13/15 V per zone). Source: EMCOD manufacturer specifications
Check voltage at the load
Choose a tap so the fixture voltage stays inside that fixture’s published window after drop. Nearby fixtures on a short run can see nearly the tap voltage. Far fixtures see less. The correct tap is a field and design result, not a catalog slogan.
Capacity and family architecture: How to Choose and Size a Landscape Lighting Transformer. Families: ESL, Simple, EMT, SMT.
Voltage-drop calculation
This page does not repeat the wire-gauge arithmetic. Use Landscape Lighting Voltage Drop for current, conductor resistance, and worked examples.
Common questions
Does every EMCOD landscape transformer have 12 V and 15 V taps?
No. Confirm the exact MPN specification or installation sheet. Sourced ESL and Simple sheets print 12/15 VAC. EMT and SMT documents in the approved set print different tap structures. Catalog records may only say Multi-tap.
Should I use the 15 V tap on a long run?
Only if the voltage at the fixture stays inside that fixture’s window after drop. A higher tap can overvoltage nearby fixtures. Check the run, load, cable, and field voltage. Use the voltage-drop guide for the calculation.
Can I read EMT300SS-E taps from the model number?
No. EMT wattage class and stainless family are encoded; exact tap voltages are on the specification sheet. Do not assume EMT300SS-E uses the EMT-22E 12–22 VAC set.
Related EMCOD products
Families and exact models this published guide actually covers. Family links are canonical product records. Exact models use machine-addressable ?variant= URLs.
- EMCOD ESL LED Drivers
Landscape transformer. Landscape transformer family whose sourced sheets document tap options. Confirm the selected MPN.
- EMCOD Simple LED Drivers
Landscape transformer. Landscape transformer family whose sourced sheets document tap options. Confirm the selected MPN.
- EMCOD EMT LED Drivers
Landscape transformer. Multi-tap landscape family. Exact tap voltages stay on the selected specification sheet.
- EMCOD SMT LED Drivers
Landscape transformer. Landscape transformer family whose sourced sheets document tap options. Confirm the selected MPN.
Exact models referenced
- EMCOD ESL100W
Landscape transformer in ESL. Sourced ESL sheet prints 12/15 VAC taps.
- EMCOD EMT300SS-E
Landscape transformer in EMT. Current catalog EMT example; tap voltages are not invented from the MPN.
- EMCOD EMT300SS-22E
Landscape transformer in EMT. Sourced 12–22 VAC tap-set contrast to EMT-E.
- EMCOD SMT300W
Landscape transformer in SMT. SMT install lists 12/13/15 V per zone; confirm the selected sheet.
Technical Sources & References
- EMCOD Lighting Group — ESL100W specification sheetManufacturer specification sheet
- EMCOD Lighting Group — EMT150SS-E specification sheetManufacturer specification sheet
- EMCOD Lighting Group — EMT300SS-22E specification sheetManufacturer specification sheet
- EMCOD Lighting Group — SMT300W installation instructionsManufacturer installation instructions
- Projekt Supply catalog / EMCOD Lighting Group — EMT Series familyManufacturer catalog / Projekt catalog record